Fire rated barriers for eliminating damp and cold bridging around doors, windows and sills for cavities over 150mm up to 300mm
Independently tested by Warrington Fire to achieve 60 minutes fire-rating and minimum 15 minutes insulation.
Suitable for cavities over 150mm up to 300mm.
Compliant with Building Regulation Approved Documents C, B, L1 and L2 and satisfies BRE document ‘Thermal Insulation: avoiding risks’.
Uses:
Please note that these product properties are not a replacement for the manufacturer's literature and it is always recommended that Timloc Building Products is consulted before specifying.
|
|
||
| Fire Rated (?) | ||
| Fire Rating (?) | 60 minutes | |
| Standards (?) | Complies with ‘Part L’ accredited construction details , Complies with the Scottish Building Standards ‘Technical handbook’ , ISO 14001 , ISO 9001 , Meets all relevant British Standards , NHBC , Satisfies BRE document ‘Thermal insulation: avoiding risks’ | |
|
|
||
| Length (?) | 2400 mm | |
| Width (?) | 175 mm | |
|
|
||
| Uniclass (?) | Pr_35_90_50 Masonry walling ancillary products | |
|
|
||
| Product ID Number (?) | FR60/175 | |
| Quantity Per Pack (?) | 2 | |
|
|
||
| Colour (?) | Grey | |
| Material (?) | Polyethylene bag encapsulates insulation for moisture protection , PVC-U , Rockfibre mineral wool (FR) insulation 0.034W/m2K | |
|
|
||
| Features (?) | Durable and resistant to decay , Exceeds the minimum thermal resistance path of 0.45m2K/W stipulated in ‘Part L’ accredited construction details , Global warming potential of zero , Insulation option to suit your requirements both thermal and fire rated , Ozone depletion potential of zero , Rigid profile extrusion allows both first and second fix , Suitable for flush jambs and sill positions , Supplied with 4 metal fixing flanges that must be slotted into place , Thermal conductivity of 0.034W/m2K | |